drac
DRAC
This role supports configuration of BIOS settings and RAID on Dell machines with an iDRAC card.
This role will apply changes required to reach the configuration specified by the user, using the Web Services Management (WSMAN) protocol. If there are any existing pending changes, whether committed or uncommitted, these will be taken into account and applied in addition to the specified changes. Where any pending changes conflict with specified changes, those specified as arguments to this module take priority.
If the drac_reboot
argument is specified as true
, the system will be
rebooted to apply the changes.
There may be some cases where the changes could not be applied without
rebooting the system at least once. In these cases, the role will fail if
the user has specified the reboot argument as false.
Since the system may be rebooted (up to 3 times in total) to apply the
configuration, this role may take a long time to execute.
Requirements
The role provides a module, drac
, that is dependent upon the
python-dracclient
package version 2.0.0 or greater. This must be installed in
order for this module to function correctly.
Role Variables
The following variables may be set for this role:
drac_address
: The address to use when communicating with the DRAC.
drac_username
: The username to use when communicating with the DRAC.
drac_password
: The password to use when communicating with the DRAC.
drac_bios_config
: Dict mapping BIOS configuration names to their desired values.
drac_raid_config
: List of virtual disk configurations. Each item should be a dict containing
the following items: name
, raid\_level
, span\_length
, span\_depth
,
pdisks
. The pdisks
item should be a list of physical disk IDs.
drac_reboot
: Whether to reboot the node (if required) once the configuration has been
applied.
drac_timeout
: Time in seconds to wait for pending operations to complete. 0 means to wait
forever.
drac_interval
: Time in seconds between polling for operations to complete.
drac_check_mode
: Whether to execute the drac
module in check mode. Defaults to unset which
uses the global check mode.
drac_result
: Will be set to the registered result of the drac
module.
Dependencies
None
Example Playbook
This role may be used as follows:
- hosts: dell-servers
roles:
- role: stackhpc.drac
drac_address: 1.2.3.4
drac_username: foo
drac_password: bar
drac_bios_config:
NumLock: 'On'
SysProfile: 'PerfOptimized'
drac_raid_config:
- name: Virtual disk 1
raid_level: 1
span_length: 2
span_depth: 1
pdisks:
- 'Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1'
- 'Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1'
License
BSD
Author Information
- Authors: Mark Goddard & Stig Telfer
- Company: StackHPC Ltd
- Website: https://stackhpc.com
Role to configure the BIOS and RAID on Dell machines with an iDRAC card.
ansible-galaxy install stackhpc/drac